Schneider_Electric TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 115A, 24 V AC 50/60 Hz coi 2500876342

£511.88 inc VAT £426.57 ex VAT

TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 115A, 24 V AC 50/60 Hz coil. range: TeSys - product name: TeSys D - product or component type: contactor - device short name: LC1D - contactor application: motor control, resistive load - utilisation category: AC-1, AC-3, AC-4 - poles description: 3P - pole contact composition: 3 NO - [Ue] rated operational voltage: <= 1000 V AC 25...400 Hz for power circuit, <= 300 V DC for power circuit - [Ie] rated operational current: 115 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 200 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power kW: 18.5 kW at 400 V AC 50/60 Hz AC-4, 30 kW at 220...230 V AC 50/60 Hz AC-3, 55 kW at 380...400 V AC 50/60 Hz AC-3, 59 kW at 415...440 V AC 50/60 Hz AC-3, 65 kW at 1000 V AC 50/60 Hz AC-3, 75 kW at 500 V AC 50/60 Hz AC-3, 80 kW at 660...690 V AC 50/60 Hz AC-3 - motor power hp: 100 hp at 575/600 V AC 50/60 Hz for 3 phases motors, 30 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 40 hp at 230/240 V AC 50/60 Hz for 3 phases motors, 75 hp at 460/480 V AC 50/60 Hz for 3 phases motors - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - Irms rated making capacity: 1260 A at 440 V for power circuit conforming to IEC 60947, 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1 - [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 1100 A <= 40 °C 1 s power circuit, 120 A 500 ms signalling circuit, 140 A 100 ms signalling circuit, 250 A <= 40 °C 10 min power circuit, 550 A <= 40 °C 1 min power circuit, 950 A <= 40 °C 10 s power circuit - associated fuse rating: 10 A gG for signalling circuit, 200 A gG at <= 690 V coordination type 2 for power circuit, 250 A gG at <= 690 V coordination type 1 for power circuit - [Ui] rated insulation voltage: 1000 V for power circuit conforming to IEC 60947-4-1, 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL, 600 V for signalling circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for signalling circuit conforming to IEC 60947-1 - electrical durability: 0.8 Mcycles 200 A AC-1 at Ue <= 440 V, 0.95 Mcycles 115 A AC-3 at Ue <= 440 V - power dissipation per pole: 24 W AC-1, 7.9 W AC-3 - protective cover: with - mounting support: plate, rail - standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS (Lloyds register of shipping), RINA, UL - connections - terminals: control circuit : lugs-ring terminals - external diameter: 8 mm, power circuit : bars 1 5 x 25 mm, power circuit : lugs-ring terminals - external diameter: 25 mm - tightening torque: control circuit : 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm screw : M3.5, control circuit : 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 screw : M3.5, power circuit : 12 N.m - on bars hexagonal 13 mm screw : M8, power circuit : 12 N.m - on lugs-ring terminals hexagonal 13 mm screw : M8 - operating time: 20...50 ms closing, 6...20 ms opening - safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 - mechanical durability: 8 Mcycles.

SKU: 2500876342 Categories: , Tag:

Description

TeSys D contactor, 3p(3 NO), AC-3, <= 440 V 115A, 24 V AC 50/60 Hz coi